Controls (Symbol 2-3)

Full category name: Vaporizer Attributes of Cig-a-likes (CLs), Advanced Personal Vaporizers (APVs), E-Hookahs (EHs) and Herbal Vaporizers (HWOVs) (Group 2)

2.3     Controls (Symbol 2-3)

None of these options is inapplicable to CLs and this symbol should be designated with “X” for CLs.

External Control and controls for APVs and EHs

Currently, there are 8 alphabetic options for the APVs and EHs categories that define the controls, including external control functions and the absence or availability of means to regulate Air Flow and Liquid Feed.

A – without External Control, with Non-Adjustable Air Flow and Non-Adjustable Liquid Feed

B – without External Control, with Non-Adjustable Air Flow and Adjustable Liquid Feed

C – without External Control, with Adjustable Air Flow and Non-Adjustable Liquid Feed

D – without External Control, with Adjustable Air Flow and Adjustable Liquid Feed

E – with External Control, Non-Adjustable Air Flow and Non-Adjustable Liquid Feed

F – with External Control, Non-Adjustable Air Flow and Adjustable Liquid Feed

G – with External Control, Adjustable Air Flow and Non-Adjustable Liquid Feed

H – with External Control, Adjustable Air Flow and Adjustable Liquid Feed

 

External Control and controls for HWOVs

Currently, there are 11 alphabetic options for the HWOVs category that define the controls, including external control functions and the absence or availability of means to regulate Air Flow and Liquid Feed. By adjusting the liquid feed, we mean adjusting the flow of wax or oil to the wick.

For devices that use wax or oil, only the characters from A to H apply.

For devices that use dry herb and cigarette sticks, only symbols I, J, K, L are applicable.

A – without External Control, with Non-Adjustable Air Flow and Non-Adjustable Liquid Feed (Wax or Oil)

B – without External Control, with Non-Adjustable Air Flow and Adjustable Liquid  (Wax or Oil)

C – without External Control, with Adjustable Air Flow and Adjustable Liquid Feed (Wax or Oil)

D – with External Control, Non-Adjustable Air Flow and Non-Adjustable Liquid (Wax or Oil)

E – with External Control, Non-Adjustable Air Flow and Adjustable Liquid Feed (Wax or Oil)

F – with External Control, Adjustable Air Flow and Non-Adjustable Liquid Feed (Wax or Oil)

G – with External Control, Adjustable Air Flow and Adjustable Liquid Feed (Wax or Oil)

H – without External Control, Non-Adjustable Air Flow (For Dry Herb)

I – with External Control, Non-Adjustable Air Flow (For Dry Herb)

J – without External Control, Adjustable Air Flow (For Dry Herb)

K – with External Control, Adjustable Air Flow (For Dry Herb)

 

External Control and controls for HDs

Currently, there are 16 alphabetic options for the HDs category that define the controls, including external control functions and the absence or availability of means to regulate Air Flow and Liquid Feed.

 

A – Without External Control and next features:

For Lp: Non-Adjustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Non-Adjustable Air Flow

                                 

B – With External Control and next features:

For Lp: Non-Adjustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Non-Adjustable Air Flow

C – Without External Control  and next features:

For Lp: Adjustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Non-Adjustable Air Flow

 

D – With External Control  and next features:

For Lp: Adjustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Non-Adjustable Air Flow

 

E – Without External Control and next features:

For Lp: Non-Adjustable Air Flow and Adjustable Liquid Feed

For DHp: Non-Adjustable Air Flow

 

F – With External Control and next features:

For Lp : Non-Adjustable Air Flow and Adjustable Liquid Feed

For DHp :Non-Adjustable Air Flow

 

G – Without External Control and next features:

For Lp: Adjustable Air Flow and Adjustable Liquid Feed

For DHp: Non-Adjustable Air Flow

 

H – With External Control and next features:

For Lp: Adjustable Air Flow and Adjustable Liquid Feed

For DHp: Non-Adjustable Air Flow

 

I – Without External Control and next features:

For Lp: Non-Adjustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Adjustable Air Flow

J – With External Control and next features:

 

For Lp: Non-Adjustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Adjustable Air Flow

 

K – Without External Control andnext features:

For Lp: Adjustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Adjustable Air Flow

 

L – With External Control and next features:

For Lp: djustable Air Flow and Non-Adjustable Liquid Feed

For DHp: Adjustable Air Flow

 

M – Without External Control next features:

For Lp: Non-Adjustable Air Flow and Adjustable Liquid Feed

For DHp: Adjustable Air Flow

 

N – With External Control next features:

For Lp: Non-Adjustable Air Flow and Adjustable Liquid Feed

For DHp: Adjustable Air Flow

 

O – Without External Control and next features:

For Lp : Adjustable Air Flow and Adjustable Liquid Feed

For DHp : Adjustable Air Flow

 

P – With External Control and next features:

For Lp: Adjustable Air Flow and Adjustable Liquid Feed

For DHp: Adjustable Air Flow

 

2.3.1     Controls of APVs and EHs

A – Without External Control, with Non-Adjustable Air Flow and Non-Adjustable Liquid Feed

This option includes devices with no external controls, non-adjustable air flow and non-adjustable liquid feed.

     

B – Without External Control, with Non-Adjustable Air Flow and Adjustable Liquid Feed

This option includes devices without external control, without adjustable air flow and with adjustable liquid feed.

 

C – Without External Control, with Adjustable Air Flow and Non-Adjustable Liquid Feed

This option includes devices without external control, with adjustable liquid feed and without adjustable air flow

 

D – Without External Control, with Adjustable Air Flow and Adjustable Liquid Feed

This option includes devices without external control and with adjustable liquid feed and adjustable air flow

 

E – With External Control, Non-Adjustable Air Flow and Non- Adjustable Liquid Feed

This option includes devices with external control, without adjustable air flow and without adjustable liquid feed.

 

F – With External Control, Non-Adjustable Air Flow and Adjustable Liquid Feed

This option includes devices with external control, without adjustable air flow and with adjustable liquid feed

 

G – With External Control, with Adjustable Air Flow and Non-Adjustable Liquid Feed

This option includes devices with external control and adjustable air flow and without adjustable liquid feed.

 

H – With External Control, Adjustable Air Flow and Adjustable Liquid Feed

This option includes devices with external control, adjustable liquid feed and adjustable air flow.

 

2.3.2           Controls of HWOVs

 A – Without External Control, without adjustable Airflow and without adjustable Liquid Feed (for Wax and Oil devices)

This option includes devices for wax or oil, without external control, with Non-Adjustable Air Flow and Non-Adjustable Liquid Feed (Wax or Oi

 

B – Without External Control, without adjustable Airflow and with adjustable Liquid Feed (for Wax and Oil devices)

This option includes devices for wax or oil, without external control, with Non-Adjustable Air Flow and with Adjustable Liquid Feed (Wax or Oil)

 

C – Without External Control, with adjustable Airflow and with adjustable Liquid Feed (for Wax and Oil devices)

This option includes devices for wax or oil, without external control, with Adjustable Air Flow and with Adjustable Liquid Feed (Wax or Oil)

 

D – With External Control, without adjustable Airflow and without adjustable Liquid Feed (for Wax and Oil devices)

This option includes devices for wax or oil, with external control, without Adjustable Air Flow and without Adjustable Liquid Feed (Wax or Oil).

 

E – With External Control, without adjustable Airflow and with adjustable Liquid Feed (for Wax and Oil devices)

This option includes devices for wax or oil, with external control, without Adjustable Air Flow and with Adjustable Liquid Feed (Wax or Oil)

 

F – With External Control, with adjustable Airflow and without adjustable Liquid Feed (for Wax and Oil devices)

This option includes devices for wax or oil, with external control, with Adjustable Air Flow and without Adjustable Liquid Feed (Wax or Oil).

 

G – With External Control, with adjustable Airflow and with adjustable Liquid Feed (for Wax and Oil devices)

This option includes devices for wax or oil, with external control, with Adjustable Air Flow and with Adjustable Liquid Feed (Wax or Oil).

 

H – Without External Control, without adjustable Airflo (for Dry Herb devices)

This option includes devices for dry herb s and cigarette sticks, without external control and without Adjustable Air Flow.

 

I – With External Control, without adjustable Airflow (for Dry Herb devices)

This option includes devices for dry herb s and cigarette sticks, with external control and without Adjustable Air Flow.

 

J – Without External Control, with adjustable Airflow(for Dry Herb devices)

This option includes devices for dry herb s and cigarette sticks, with external control and without Adjustable Air Flow.

 

K – With External Control, with adjustable Airflow (for Dry Herb devices)

This option includes devices for dry herb s and cigarette sticks, with external control and with Adjustable Air Flow.

 

2.3.3           Controls of HDs

 A – Without External Control and without Adjustable control features

This option includes devices without external control, without adjustable airflow for Lp, without adjustable liquid feed for Lp and also without adjustable airflow for DHp and without adjustable temperature for DHp.

 

B – With External Control and without Adjustable control features

This option includes devices with external control, without adjustable airflow for Lp, without adjustable liquid feed for Lp and also without adjustable airflow for DHp and without adjustable temperature for DHp.

 

C – Without External Control and with adjustable air flow (Lp)

This option includes devices without external control and next features:

 For Lp: with adjustable air flow and without adjustable liquid feed.

 For DHp: without adjustable airflow and without adjustable temperature.

 

D – With External Control and with adjustable air flow (Lp)

This option includes devices with external control and next features:

 For Lp: with adjustable air flow and without adjustable liquid feed.

 For DHp: without adjustable airflow and without adjustable temperature.

 

E – Without External Control and with adjustable liquid feed (Lp)

This option includes devices without external control and next features:

 For Lp: without adjustable air flow and with adjustable liquid feed.

 For DHp: without adjustable airflow and without adjustable temperature.

 

F – With External Control and with adjustable liquid feed (Lp)

This option includes devices with external control and next features:

 For Lp: without adjustable air flow and with adjustable liquid feed.

 For DHp: without adjustable airflow and without adjustable temperatur

 

G – Without External Control and with adjustable air flow and adjustable liquid feed (Lp)

This option includes devices without external control and next features:

For Lp: with adjustable air flow and with adjustable liquid feed.

For DHp: without adjustable airflow and without adjustable temperature.

 

H – With External Control and with adjustable air flow and adjustable liquid feed (Lp)

This option includes devices with external control and next features:

For Lp: with adjustable air flow and with adjustable liquid feed.

For DHp: without adjustable airflow and without adjustable temperature.

 

I – Without External Control and with adjustable air flow (DHp)

This option includes devices without external control and next features:

For Lp: without adjustable air flow and without adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

J – With External Control and with adjustable air flow (DHp)

This option includes devices with external control and next features:

For Lp: without adjustable air flow and without adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

K – Without External Control and with adjustable air flow (Lp) and (DHp)

This option includes devices without external control and next features:

For Lp: with adjustable air flow and without adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

L – With External Control and with adjustable air flow (Lp) and (DHp)

This option includes devices with external control and next features:

For Lp: with adjustable air flow and without adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

M– Without External Control and with adjustable liquid feed (Lp) and with adjustable air flow (DHp)

This option includes devices without external control and next features:

For Lp: without adjustable air flow and with adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

N– With External Control and with adjustable liquid feed (Lp) and with adjustable air flow (DHp)

This option includes devices with external control and next features:

For Lp: without adjustable air flow and with adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

O – Without External Control and with adjustable air flow, adjustable liquid feed (Lp) and with adjustable air flow (DHp)

This option includes devices without external control and next features:

For Lp: with adjustable air flow and with adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

P – With External Control and with adjustable air flow, adjustable liquid feed (Lp) and with adjustable air flow (DHp)

This option includes devices with external control and next features:

For Lp: with adjustable air flow and with adjustable liquid feed.

For DHp: with adjustable airflow and without adjustable temperature.

 

 

file-text2 reddit envelop search